Description
Deleting devices which were changed in the background process may occasionally show an non-critical error message.
Workaround / Solution
The message can be ignored. It is only an indicator of conflicting changes, and does not lead to a crash, functionality or data loss.
Description
RayVentory Scan Engine may hang upon launching after migration from 12.2 SP5 with any CyberArk credentials. This is caused by an incompatible credentials type, which were renamed in version 12.3. The problem does not occur, when no CyberArk credentials are used.
Workaround / Solution
Temporarily remove CyberArk credentials before migrating, and restore them after the first launch of RayVentory Scan Engine 12.3.
Description
Internal HTTP server for incoming files may fail with HTTP error 500 when basic authentication is set and no SSL is used to secure the connection.
Workaround / Solution
Use basic authentication with a secure connection over SSL/TLS.